Skip to main content

Column Rebar — Classic — Settings reference

Walkthrough and screenshots · Coverage CSV

Basic cage creation is verified. The instructional family solid is 3048 mm high while its system length is 4000 mm: reinforcement extends above the solid. Do not treat this fixture as a coordinated final detail. Additional closed ties, crossties, separated bars and foundation settings are preview demonstrations. The separate frame generation failed inside Revit; no advanced successful result is claimed. Re-running can duplicate reinforcement.

Control labels match the recorded installation. Settings below describe UI/source behavior; they are not a claim that every combination generated successfully. Refer to the walkthrough for the exact exercised values and evidence.

ControlUnits / optionsBehavior and interactions
Level list / column graphicSelect one level in stackCurrent host dimensions and settings.
Uniform distribution Rebar SettingsLayout radioCx/Cy perimeter arrangement.
Rebar Number Cx / CyInteger; tested 4 / 3Counts include corners. Rectangle total=2Cx+2Cy−4. 3/3→8; 4/3→10.
Main Bar DiameterLoaded type; D20 testedDiameter of main longitudinal bars. Count is separate.
Use Distribution BarBooleanEnable separate distribution diameter; inspect affected positions.
Distribution Bar DiameterLoaded typeUsed only when distribution bars are enabled.
Total Bar / Reinforcement Area / RatioCount; cm²; %Calculated preview information, not a generation report.
Separated distributionLayout radioSeparate outer/inner controls and diameter state.
Outer layer Rebar NumbersIntegerOuter arrangement count; check total and preview.
Inner layer Rebar NumbersEnable + integerAdds configured inner arrangement when enabled.
Main Stirrup DiameterLoaded type; D8 testedMain perimeter ties; additional tie diameter is elsewhere.
CrosstieRadio + section bar clickClick highlighted bar position; inspect crossing tie preview.
Closed tieRadio + two same-side bar picksTwo different bars on same side; identical or different-side picks can error.
Apply for other levelsCopy settingsRequires more than one level; verify each recipient.
Floor Framing type / depthDetected association / mmVerify host intersection; null is not confirmed detection.
Top Cover thickness / Other Cover thicknessmm; 25 in fixtureSeparate top and remaining covers.
Starter Bar SettingsBooleanEnables foundation starter arrangement. Runtime advanced case blocked.
Separate 2 segments at Starter BarBooleanSeparate starter and upper bar segments.
Stirrup Spacing — FoundationEnable + mm; 200 exampleFoundation ties only when enabled.
Hm / Lbmm; 1000 / 350 exampleStarter geometry dimensions shown in sketch.
Direction arrows / ReverseFour directions / reverseChange foundation bar direction.
Spread Stirrup into bottom of Beam / FloorRadioStop distribution at underside.
Spread Stirrup into top of Beam / FloorRadioEnable additional distribution through support depth.
Stirrup Spacing / Stirrup NumbersRadio + mm / countAlternative support-depth layout when spread-to-top enabled.
Distance to first Stirrupmm; 50 exampleOffset of first tie.
Uniform / Distribution A1,A2,A1 / Distribution A1,A2RadioOne spacing / end-middle-end / two zones.
A1 / A2mm; 100 / 200 exampleZone spacing; smaller spacing increases density.
MinimumEnable + mm; 450Candidate minimum L1 extent.
Clearance height divide byEnable + divisor; 5Candidate clear-height fraction for L1.
Column section heightBooleanCandidate section dimension; greatest enabled criterion controls L1.
Cover full lap splice zoneBooleanExtend dense region to lap zone.
Top zone separate, valueEnable + mmSeparate top zone extent.
Get same spacing with main StirrupBooleanAdditional ties inherit main spacing; otherwise custom field.
Diameter / Hook Type — additional tiesLoaded typesApplies to internal ties, not main tie diameter.
Custom additional spacingmm; 150 demonstratedEnabled when inheritance is off.
Rebar Hook Length: Fixed Length / Diametermm / multiplier; 200 / 10 exampleAlternative hook length rules.
Add Elevation / Add PartitionBooleansWrite reinforcement information.
Bend Bar if e ≤mm; 75 exampleSection-offset condition.
Ratio Hd/e ≥Ratio; 6 exampleRequired bend-rise to offset ratio.
Hooks bending / Starter Bar for continuousRadioTop termination versus continuity starter.
Lap Length / Rebar Hook Length — lap group×D; 35 / 30 exampleSeparate lap and anchorage multipliers.
Bend Bar at Lapping Zone to avoid conflictBooleanOffset geometry at overlap.
Group Bars with same Rebar NumberBooleanGrouping by assigned bar number.
Distance from column bottom L / Middle of ColumnRadio + mm; 100 exampleReference for lap position.
Distance between 2 Laps×D; 5 exampleSeparation between staggered splice locations.
Lap at 1 position / Lap at 2 positionsRadioSingle or staggered positions.
Floor Beam Settings / Select Floor Beam manually / Automatically find BeamsRadio + default depthDefault depth, interactive selection, or automatic association.
Beam Or FloorPick + FinishAvailable in manual association mode.
Run / Close / tabsCreate / exit / navigateRun saves settings and creates; Close is not a generation step. No automatic replacement should be assumed.